The ideal channel for all your showering questions. With a variety of videos explaining what is an electric shower to how to commission the Safeguard thermostatic shower, you will find everything here. Also why not meet the Triton Technical team and put a face to the voice.
Triton Showers are leading manufacturers of all types of showers including Electric Showers and Mixer Showers. Triton has been at the heart of bathrooms for more than 30 years providing the biggest shower range in Britain.
Visit www.tritonshowers.co.uk for a full list of our showers, and the option to use the Help Me Choose section, which gives you the ability to find the perfect Mixer Shower, Electric Shower or Power Shower to suit your showering needs.
Triton Showers are leading manufacturers of all types of showers including Electric Showers and Mixer Showers. Triton has been at the heart of bathrooms for more than 30 years providing the biggest shower range in Britain.
Visit www.tritonshowers.co.uk for a full list of our showers, and the option to use the Help Me Choose section, which gives you the ability to find the perfect Mixer Shower, Electric Shower or Power Shower to suit your showering needs.
Triton Showers - Corner Shower Kit Explained
Introducing the Corner Shower Kit from Triton Showers. Specifically designed to fit into a corner of a shower enclosure to optimise available space for maximum showering enjoyment.
Available in white or chrome as either a full kit (including shower head and hose) or as a shower rail only.
🔗 Links
Corner Shower Kit (Chrome): www.tritonshowers.co.uk/shower-accessories/shower-kits/corner-shower-kit-chrome
Corner Shower Kit (White/Chrome): www.tritonshowers.co.uk/shower-accessories/shower-kits/corner-complete-riser-kit-white-chrome
Corner Shower Riser Rail (Chrome): www.tritonshowers.co.uk/shower-accessories/shower-rails/corner-shower-riser-rail-chrome
Corner Shower Riser Rail (White/Chrome): www.t...
Available in white or chrome as either a full kit (including shower head and hose) or as a shower rail only.
🔗 Links
Corner Shower Kit (Chrome): www.tritonshowers.co.uk/shower-accessories/shower-kits/corner-shower-kit-chrome
Corner Shower Kit (White/Chrome): www.tritonshowers.co.uk/shower-accessories/shower-kits/corner-complete-riser-kit-white-chrome
Corner Shower Riser Rail (Chrome): www.tritonshowers.co.uk/shower-accessories/shower-rails/corner-shower-riser-rail-chrome
Corner Shower Riser Rail (White/Chrome): www.t...
Просмотров: 67
Видео
ENVi® - Next generation electric showers
Просмотров 11 тыс.8 месяцев назад
Discover the next generation of personalised electric showering with ENVi®. Select a pre-set programme or create your own shower profile. ENVi® features full-colour digital display that provides feedback on individual shower use. Triton. For A Cleaner Conscience 🔗 Links Sustainability: www.tritonshowers.co.uk/sustainability Product range: www.tritonshowers.co.uk/envi 👍 Follow us Facebook: fac...
ENVi® How To Guide: Customise Your Usage Statistics
Просмотров 4379 месяцев назад
For more information on ENVi® or if you need more support please click on our support page here: www.tritonshowers.co.uk/envisupport For more information about ENVi® generally, check out our ENVi® page: www.tritonshowers.co.uk/envi
ENVi® How To Guide: Setting Timers and Eco Mode.
Просмотров 1919 месяцев назад
For more information on ENVi® or if you need more support please click on our support page here: www.tritonshowers.co.uk/envisupport For more information about ENVi® generally, check out our ENVi® page: www.tritonshowers.co.uk/envi
ENVi® How To Guide: Overview
Просмотров 2,3 тыс.9 месяцев назад
For more information on ENVi® or if you need more support please click on our support page here: www.tritonshowers.co.uk/envisupport For more information about ENVi® generally, check out our ENVi® page: www.tritonshowers.co.uk/envi
ENVi® How To Guide: Understanding User Profiles
Просмотров 2049 месяцев назад
For more information on ENVi® or if you need more support please click on our support page here: www.tritonshowers.co.uk/envisupport For more information about ENVi® generally, check out our ENVi® page: www.tritonshowers.co.uk/envi
Different home water systems for your shower explained
Просмотров 34411 месяцев назад
Looking to understand more about different home water systems and find the best shower for your system? Whether you are looking for a shower suited to a high pressure, low pressure or cold mains system, the Triton shower range has a solution for you. 🔗 Links Triton Showers website: www.tritonshowers.co.uk 👍 Follow us Facebook: tritonshowers Instagram: triton_showers ...
ENVi® Thermostatic Electric Shower | Tri-Hub unit
Просмотров 2,8 тыс.Год назад
Discover the next generation of personalised electric showering with ENVi®. Select a pre-set programme or create your own shower profile. ENVi® features full-colour digital display that provides feedback on individual shower use. Instant hot water is heated on demand and drawn from the cold mains feed. ENVi® is no different, with the exception of the thermostatic shower unit being located aw...
ENVi® Thermostatic Electric Shower | Get the look
Просмотров 1,5 тыс.Год назад
Discover the next generation of personalised electric showering with ENVi®. Select a pre-set programme or create your own shower profile. ENVi® features full-colour digital display that provides feedback on individual shower use. Get the look Select from three premium finishes and four flexible kit options to suit any style of bathroom. Triton. For A Cleaner Conscience 🔗 Links Sustainability:...
ENVi® Thermostatic Electric Shower | Intuitive Controller
Просмотров 440Год назад
Discover the next generation of personalised electric showering with ENVi®. Select a pre-set programme or create your own shower profile. ENVi® features full-colour digital display that provides feedback on individual shower use. Triton. For A Cleaner Conscience 🔗 Links Sustainability: www.tritonshowers.co.uk/sustainability Product range: www.tritonshowers.co.uk/envi 👍 Follow us Facebook: fac...
Triton Instaflow Stored Water Heater - Step-by-step Installation Guide
Просмотров 5 тыс.Год назад
In this video, see how to install the Triton Instaflow Stored Water Heater. The Instaflow’s compact size means the product is easy to install, resulting in little downtime for you when you install! It is designed for under-sink situations or can be tucked away in a discreet location. With easy to operate controls, it gives quick heat up times with variable temperature settings to a maximum of 7...
Triton Omnicare Electric Shower - Step-by-step Installation Guide
Просмотров 5 тыс.Год назад
In this video, see how to install the Triton Omnicare and Omnicare Design thermostatic electric shower and learn how the Omnicare range combines the principles of design, safety and simplicity. 🔗 Links Omnicare Electric Shower: www.tritonshowers.co.uk/omnicare-thermostatic-electric-shower Omnicare Design Electric Shower with Extended Kit: www.tritonshowers.co.uk/omnicare-design-thermostatic-sho...
Every Drop Makes A Difference | Save Water, Save Energy, Save Money
Просмотров 10 тыс.2 года назад
Every Drop Makes A Difference | Save Water, Save Energy, Save Money
Triton Showers & Marine Conservation Society Partnership
Просмотров 1952 года назад
Triton Showers & Marine Conservation Society Partnership
Replacing the pressure relief device on the Triton T80Z Thermostatic Fast-Fit Electric Shower
Просмотров 26 тыс.2 года назад
Replacing the pressure relief device on the Triton T80Z Thermostatic Fast-Fit Electric Shower
Replacing the solenoid valve on the Triton T80Z Thermostatic Fast-Fit Electric Shower
Просмотров 6 тыс.2 года назад
Replacing the solenoid valve on the Triton T80Z Thermostatic Fast-Fit Electric Shower
Triton T80Z Thermostatic Fast-Fit Electric Shower - Cable & Water Entry Points Explained
Просмотров 2,9 тыс.2 года назад
Triton T80Z Thermostatic Fast-Fit Electric Shower - Cable & Water Entry Points Explained
Triton T80Z Fast-Fit Electric Shower - Cable & Water Entry Points Explained
Просмотров 3,9 тыс.2 года назад
Triton T80Z Fast-Fit Electric Shower - Cable & Water Entry Points Explained
Replacing the solenoid valve on the Triton T80 Pro-Fit Electric Shower
Просмотров 18 тыс.2 года назад
Replacing the solenoid valve on the Triton T80 Pro-Fit Electric Shower
Replacing the pressure relief device on the Triton T80 Pro-Fit Electric Shower
Просмотров 33 тыс.2 года назад
Replacing the pressure relief device on the Triton T80 Pro-Fit Electric Shower
Triton T80 Pro-Fit Electric Shower - Cable & Water Entry Points Explained
Просмотров 2,8 тыс.2 года назад
Triton T80 Pro-Fit Electric Shower - Cable & Water Entry Points Explained
Replacing the thermistor on the Triton Omnicare Thermostatic Electric Shower
Просмотров 3,3 тыс.2 года назад
Replacing the thermistor on the Triton Omnicare Thermostatic Electric Shower
Replacing the solenoid valve on the Triton Omnicare Thermostatic Electric Shower
Просмотров 8 тыс.2 года назад
Replacing the solenoid valve on the Triton Omnicare Thermostatic Electric Shower
Replacing the pressure relief device on the Triton Omnicare Thermostatic Electric Shower
Просмотров 2,6 тыс.2 года назад
Replacing the pressure relief device on the Triton Omnicare Thermostatic Electric Shower
Triton Omnicare Thermostatic Electric Shower - Cable & Water Entry Points Explained
Просмотров 5382 года назад
Triton Omnicare Thermostatic Electric Shower - Cable & Water Entry Points Explained
Adjusting the Safe Set™ on the Triton Omnicare Thermostatic Electric Shower
Просмотров 7 тыс.2 года назад
Adjusting the Safe Set™ on the Triton Omnicare Thermostatic Electric Shower
Triton Amore Electric Shower - Cable & Water Entry Points Explained
Просмотров 3,1 тыс.2 года назад
Triton Amore Electric Shower - Cable & Water Entry Points Explained
Thanks so much for this! Fixed my shower all by myself for a fiver.Also saved a lot of inconvenience.
I find that the mixing dial is very stiff and is difficult to turn especially when wet as there is no grip on dial itself. Any ideas how to fix? Thanks.
Hi if the dial is stiff this could indicate a fault on the temperature valve, in this instance we'd recommend you contact our service team for a potential visit on 02476 372222. Kind regards, Leon.
Oh great video by the way
Hi what size copper compression fittings are use on this shower? Thanks
Just installed my Omnicare SE, but it's beeping when we turn it on and off. How do we change the dip switches so it doesn't auto turn off, but also doesn't beep?
It's not possible to turn off the timed shutdown, but you can turn off the audible feedback, we show the dip switch options on this link page 19 www.tritonshowers.co.uk/amfile/file/download/file/1272/product/3493/
New shower fitted not heating always going back to cold
Hi sorry to read about the problem, fault finding for this issue will be dependant on the model, if you still require assistance our service department on 02476 372222 should be able to assist. Kind regards, Leon.
No pictures
At 27secs. How do I get the water running to flush out debris and air from the pipe?
That bloody music !!
You look like the king of Jordan
Wow its so silent, and with wn immaculate linear flow😅
My AS2000SR doesn't seem to have a cool setting, it goes from hot to scalding hot even on the lowest settings. It is constantly set to the lowest temperature and I have to make sure the water tank isn't really hot before I shower to have a more comfortable shower, is this a solveable problem? I'm the only one in the family brave enough to use it!
This type of issue can occur if the hot/cold water feeds are not going into the correct inlets, worth checking this in the first instance, if the orientation for the pipes is correct we'd advise contacting our service team on 02476 372222 for a potential service visit.
Would replacing this stop ours dripping or does the whole valve need replacing? Thx.
If the shower is constantly dripping you would be better swapping the whole solenoid valve assembly opposed to just the coil like in the video, swapping just the coil may not remedy the problem.
Thought so, thanks for the reply.
If is a pipe from ceiling under unit can that drop the preasure or would improveing to fit in the top of unit
Thanks! This saved us calling out a professional, we sorted out our shower within 2 minutes.
What does the orange bit do
If you're referring to the orange rectangular piece inside the shower, this is a pressure flag, which sits behind low pressure window. This would move in conjunction with the pressure switch up and down to show you if the shower is low pressure or not. Kind regards, Leon.
You are filming too far away
I have bought yesterday from Screwfix. I gonna install today. This video is very helpful. Thanks !
If pipe entry is from rear as in video it says in instructions to seal around with mastic. But does not show this on video.
Looks easy enough unless, like me, you can barely see the cover screws never mind loosen them! The downside of getting old. 😬
Hi I change my triton shower for this new Omnicare but the pressure is going down the old one are much power any way to improve back pressure thanks
What position should the hot and cold dial be at when placing the face plate on ....... the temp guage doesnt make sense
For fitting the cover and aligning the dials we have step by step instructions on how to do this in our manual shown on this link www.tritonshowers.co.uk/amfile/file/download/file/318/product/3442/ found on pages 18/19. Kind regards, Leon.
But...why
Hi I’ve fitted the T 80 z and can’t get any heat at all what might be the problem thanks in advance, and great content
It would be worth in the first instance checking the water pressure going to the product, if the minimum water pressure requirement is not being met then the elements in the shower won't activate. If the water pressure is okay it would be worth contacting our service team on 02476 372222
No silicone around the sides of the unit? What about protecting the screw holes, ans water pipe and electrical cable hole?
Hi we say not to tile up to or seal around any part of the unit using silicone sealer after fixing it to the wall, this is specified on page 3 section 1.5 www.tritonshowers.co.uk/amfile/file/download/file/1140/product/3125/
Perfect. The water is now so hot I can see steam! Such an easy solution. Thank you.
Hello I moved into a property with this shower in it When i turn it on, it takes about 30 seconds for the water to go from completely cold to ideal What would be causing this? The previous house i lived, had a different old shower, which never did this
No mention of the correct compression fitting to use on the water inlet! Are copper olives ok or do you also need a pipe insert? (TSM???)
I used brass olive compression ring and worked ok.
8 and 11 litres p/m at what temperature. If it is at cold water or 40 degrees C makes a shower usable or not 3L p/m is pointless.
It may be useful to someone: but, the part at 3:00 where the water flows steadily out the hose, that took 15 mins and some sucking ("said the actress to the bishop") before I got a steady flow on my install. Great video, thank you, very useful.
Had real issues with the switches on these.
my triton shower button doesnt work. But the ceiling pull cord turns water on but it isn't heated. any ideas? all fuses working normally
The water not heating can be caused by low water pressure, the shower will be using a pressure switch for the elements to go on. This requirements will be dependant on the kW rating of the shower. As for the on/off not working this could be an issue with the switch itself or the unit not being flat to the wall causing misalignment with the button/switch. If the installation doesn't appear to be the problem we'd recommend contacting our service team on 02476 372222.
Trident ribs shower
the best how to iv'e come across thank you.
This advice worked like a charm on our Aquas Aquamax shower. It is now getting to a nice warm temperature in the middle of winter. Thanks very much!
I don't have any connectors on the wire on mine, will I need to add these on if so do you have a link for the right ones. I have a triton alicante
So many views make me wonder if the issuenis not with triton pimps, the pressure is my house is rich but the shower is very poor and don't try to outnit in the second power because is just go hot and cold in loop...
Just fitted T80 Easi -fit plus but was unable to fit the bottom section due to not enough space because of pipe fittings but the main issue is I have power and light on the ON button but when pressed No water? Thanks for any advice
does the mails water need to be turned off when changing the Solenoid?
When changing the solenoid valve assembly the water will need to be isolated.
Just fitted same product, all work just fine, but I don't know if ok for the on off button to be light up all the time even if not in use.
The power indicator will always be on providing the shower has an electrical supply going to it, this is just to indicate there is power to the product and is intended.
If you don't push the plastic wall plugs behind the tiles, you're liable to crack the tiles as you tighten the screws.
There are some variations between Triton products that need to be mentioned. The manual for the T90 states "UNDER NO CIRCUMSTANCES MUST THE T90si BE CONNECTED DIRECTLY TO THE MAINS WATER SUPPLY". In fact, the minimum head required is only 8cm and the maximum head is 10m = 1 bar. I had to give this video a thumbs down for incomplete information.
In very cold weather, always check to see if the water supply pipe is not frozen before going after the solenoid valve. Have a look to see if the filter is blocked but you may need to bleed the air from pump before operating it again.
Just fitted one today...T90 sr .slightly different commissioning process... much easier ..I had a T90 si for about 18 years maybe longer ..Great shower good pressure & temp..a little disappointed with the temperature and pressure on new model...don't make them like they use too.
Not giving in off hot water any reason?
This could be due to the water pressure not being high enough, causing the pressure switch not to activate the element. Water pressure required will be 1bar running pressure, if the pressure is okay then it may be a potential fault and we'd offer further help on our service number 02476 372222.
Informative!
My Triton won't turn off at the shower head only with the pull cord, could it need a new solenoid coil?